Search → Understand → Confirm specification → Engineering review → RFQ
Selection guide
PM Components for Mach–Zehnder Interferometer — selection guide

PM Components for Mach–Zehnder Interferometer

Short answer For a Mach–Zehnder interferometer, use a 1×2 PM fused coupler at the split ratio the design calls for, and a PM PBS/PBC for the two polarization states. The 45° polarization-axis orientation is built at the factory, not at splicing. The coupler works on the slow axis only, and one coupler both splits and combines.

Which PM parts does a Mach–Zehnder interferometer need?

A Mach–Zehnder interferometer needs three PM parts, each with one job. A KernsOptic PM fused coupler, model 032, splits one input into the two arms or combines the two arms into one output. A KernsOptic PM polarization beam splitter/combiner, model 040, separates two orthogonal polarization states or combines two orthogonal signals into one output fiber. A KernsOptic in-line fiber optic polarizer, model 038, passes one polarization state and is the optional third part.

The comparison below is only about a Mach–Zehnder interferometer at 1550 nm on PANDA polarization-maintaining fiber with FC/APC connectors. For a fiber sensing and interferometry build, the decision turns on four things: the port configuration, the coupling ratio, the axis orientation, and the extinction ratio on the selected configuration.

PM parts for a Mach–Zehnder interferometer: the selection comparison.
PM fused couplerPM PBS/PBCIn-line polarizer
RoleSplits one input into two arms, or combines two arms into one outputSeparates two orthogonal states into Port 1 and Port 2, or combines two orthogonal signals into one output fiberPasses one polarization state; optional clean-up part
Ports1×2 or 2×2Port 1, Port 2, and Port 3SM-SM, SM-PM, or PM-PM fiber mapping
1550 nm bandCenter wavelength 1550 nm; ±15 nm bandCenter wavelength 1550 nm; ±20 nm rangeCenter wavelength 1550 nm; ±50 nm range
Extinction ratioMin. 20 dB (780–1550 nm)Min. ≥20 dB (Grade P) or ≥18 dB (Grade A), Port 3Min. ≥28 dB (980–1550 nm)
Max. power (CW)500 mW500 mW300 mW
Axis orientationSlow axis working; fast axis blocked; slow axis aligned to the FC/APC connector key45° relative orientation built at the factory; no splicing alignment neededState the fiber mapping with the request

The comparison table compares function, not a set of guaranteed specifications. Read the loss, the ratio, and the window on the selected configuration.

Which port configuration and coupling ratio fits the interferometer?

Start with a 1×2 PM fused coupler when one source splits into the reference arm and the sensing arm. A 2×2 PM fused coupler fits when the circuit has two inputs or two outputs to serve. The full port-count comparison is in the 1×2 vs 2×2 PM coupler guide; the port count does not choose the split ratio.

The split ratio follows the interferometer design. A 50/50 split is the starting point for two equal arms. Custom split ratios from 1/99 to 50/50 are available on KernsOptic model 032. State the ratio with the request: the ratio is confirmed on the selected configuration, not assumed from the port count.

Wavelength and connectors move the measured numbers. KernsOptic model 032 lists a 1550 nm center wavelength with a ±15 nm operating bandwidth, and a maximum excess loss of 0.5 dB at 1310/1550 nm. Specifications are tested at 23 °C without connectors; a connector adds 0.2 dB loss and reduces PER by about 2 dB. State the wavelength, the ratio, and the connector type together.

Can the 45° polarization-axis orientation be built at the factory?

Yes. The 45° relative polarization-axis orientation is built at the factory. All ports are terminated with FC/APC connectors at the factory, so no splicing or alignment work is needed in the laboratory to set the orientation. The orientation does not have to be implemented during fiber splicing.

State the 45° requirement with the request. The requirement belongs in the same request as the wavelength, the grade, and the Port 3 fiber type: KernsOptic model 040 lists Port 1 and Port 2 on PM Panda fiber and Port 3 on PM Panda fiber or SMF-28e. Request the optical port diagram with the quotation: the diagram shows the polarization-axis orientation on each port.

The 45° orientation is a build option on the PBS/PBC, not a property of every PM part. A KernsOptic PM fused coupler works on the slow axis only, with the slow axis aligned to the FC/APC connector key. Do not assume a coupler carries a 45° orientation; state the orientation only where the interferometer design calls for it.

Does a PM coupler work on one axis only, and can it split and combine?

A KernsOptic PM fused coupler works on one axis only. The slow axis is the working axis and the fast axis is blocked. The slow axis is aligned to the FC/APC connector key on all ports. The minimum extinction ratio on KernsOptic model 032 is 20 dB across 780–1550 nm. How extinction ratio is read, and what angular misalignment costs, is covered in the PM fiber components extinction ratio guide.

The same coupler splits and combines. One KernsOptic PM fused coupler works as a 1×2 splitter and as a 2×1 combiner. State the port configuration and the direction of use with the request.

What to confirm before quotation

Send the port count and the ratio, the wavelength and the band, the fiber type, the connector type, the 45° orientation requirement where the design calls for it, and the PBS/PBC grade and Port 3 fiber type. For KernsOptic model 032, the port count runs 1×2 or 2×2; the fiber is PM Panda fiber; the package is dia. 3.0 × 54 mm. For KernsOptic model 040, the grade runs P or A; Port 3 takes PM Panda fiber or SMF-28e; the package is dia. 5.5 × 35 mm. All three parts list an operating temperature of −5 to +70 °C. State the pigtail jacket — bare fiber or 900 µm loose tube on the PBS/PBC — and whether the ends stay bare for splicing. Start from the Couplers & Polarization family page for the full range.

Minimum quantity depends on the confirmed configuration. Prototypes are paid. Lead time depends on the configuration and is confirmed in the quotation.

Frequently Asked Questions

Can the 45° polarization-axis orientation be built at the factory?

Yes. The 45° relative polarization-axis orientation is built at the factory, and all ports are terminated with FC/APC connectors. No splicing or alignment work is needed in the laboratory to set the orientation.

Which coupling ratio fits a Mach–Zehnder interferometer?

The ratio follows the interferometer design. A 50/50 split is the starting point for two equal arms. Custom split ratios from 1/99 to 50/50 are available on the 1×2/2×2 PM fused coupler; state the ratio with the request.

Does a PM coupler pass one polarization axis only?

Yes. The slow axis is the working axis and the fast axis is blocked. The slow axis is aligned to the FC/APC connector key on all ports.

Can the same PM coupler split and combine?

Yes. The same coupler works as a 1×2 splitter and as a 2×1 combiner. State the port configuration and the direction of use with the request.

What quantity and lead time should I plan for?

Minimum quantity depends on the confirmed configuration. Prototypes are paid. Lead time depends on the configuration and is confirmed in the quotation.

Require a Custom High-Power Optical Solution?

Engineering still starts from the same set of conditions.